Replacement ballast for single TL5 luminaires. To be used with TL5 1x54W or PLL 55W
Application Code III
Type of execution IDC
Lamp type TL5/PL-L
Number of lamps 1 piece/unit
Number of products on MCB (16 A Type B) (nom.) 28
Automatic restart Yes
Input voltage 220 to 240 V
Input frequency 50 to 60 Hz
Operating frequency (nom.) 45 kHz
Ignition method Programmed start
Crest factor (max.) 1.7
Power Factor 100% load (nom.) 0.99
Ignition time (max.) 0.9 s
Functional mains voltage range (AC) -8%-+6%
Safe AC Voltage Range -10%-+10%
Earth leakage current (nom.) 0.5 mA
Inrush current duration 0.25 ms
Constant power deviation -2%/+2%
VSA factor (nom.) 1
Power losses (nom.) 4.5 W
Inrush current (max.) 24 A
Connector type input terminals WAGO 251 universal connector [ Suitable for both automatic wiring (ALF and ADS) and manual wiring]
Cable capacitance output wires mutual (nom.) 200 pF
Connector type output terminals WAGO 251 universal connector [ Suitable for both automatic wiring (ALF and ADS) and manual wiring]
Cable length live wiring 0.75 m
Wire stripping length 8.0-9.0 mm
Dual Fixture Master/Slave Not applicable [ Master/slave operation not applicable]
Input connection cross section 0.50-1.00 mm²
Output connection cross section 0.50-1.00 mm²
Cable capacitance output wires/ground (nom.) 200 pF
Rated ballast/lamp power 54/55 W
Rated lamp power on PL-L 54/55 W
System power at PL-L 56W@55 W
Lamp power on PL-L 51.5W@55 W
Power loss on PL-L 4.5W@55 W
Specified lamp power on TL5 54/55 W
System power on TL5 57.5 W@54W; 55.5W@50 W; W
Lamp power on TL5 53 W@54 W
Power loss on TL5 4.5 W@54 W
Specified lamp power on TL5 ECO 50 W
System power on TL5 ECO 54.5 W
Lamp power on TL5 ECO 51W@50 W
Power loss on TL5 ECO 4.5 W@50 W
T-environment (max.) 60 °C
T-environment (min.) -25 °C
T-storage (max.) 80 °C
T-storage (min.) -40 °C
T-housing life (nom.) 80 °C
T-housing maximum (max.) 80 °C
T-ignition (max.) 60 °C
T-ignition (min.) -25 °C
Casing L360x30x22
Nominal light output after 60 sec. 100% or EBLF
Battery voltage lamp ignition 198-254 V
Normal operating voltage (DC) 220-240 V
Battery voltage lamp during operation 176-254
Battery voltage guaranteed operation 176-275 V
Battery voltage guaranteed ignition 186-275 V
Emergency Lighting Ballast Lumen Ratio (EBLF) (Nom) 0.7 %
Nominal light output after 5 sec. 50% or EBLF
Energy efficiency index A2 BAT
IP rating IP 20 [ Ingress Protection 20]
EMI 9 kHz ... 30 MHz EN 55015 edition 7.1
EMI 30 MHz ... 1000 MHz -
Safety standard IEC 61347-2-3
Performance standard IEC 60929
Quality Standard ISO 9000:2000
Environmental standard ISO 14001
Harmonic current emission standard IEC 61000-3-2
EMC immunity standard IEC 61547
Standard option IEC68-2-6 F c
Shock standard IEC 68-2-29 Eb
Humidity standard EN 61347-2-3 clause 11
Approval marks
CE marking
ENEC certificate
VDE-EMV certificate
Temperature marking Yes
Emergency standard IEC 60598-2-22
Hum and noise level < 30 dB(A)
Full product code 872790086348200
Product name for order HF-P 154/155 TL5 HO/PLL III 220-240V IDC
EAN/UPC - Product 8711500998217
Order code 86348200
Local Code HFP15455TL5PLL
Numerator - Number per pack 1
Numerator - Boxes per outer box 12
Material no. (12NC) 913713028266
Net weight (per piece) 0.252 kg